McdeSys gets mcde_sys_battery: all batteries as one, charging, mains, minutes left. NetBSD reads the envsys(4) dictionary of /dev/sysmon as envstat(8) does (acpibat "present", "charge", "charging", "discharge rate"; acpiacad "connected"), Linux /sys/class/power_supply (energy_* or charge_*, status, Mains/USB online). The sources are in docs/reference/battery.txt. dtbar shows a fourth icon, only when there is a battery: full, half, low (red), charging; its menu says the charge, the power source and the time left. The status bar is 30 pixels an icon. Measured: on the Linux host test_sysinfo says "battery 76% ac", as /sys/class/power_supply/BAT0/capacity and AC/online do; the menu on Xvfb (build/mcde-shots/battery-menu.png) says "Battery: 76 %", "Power Source: Power Adapter". The NetBSD backend compiles and runs in the build VM, which has no battery (envstat: no drivers registered): only the no-battery case is measured there. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
142 lines
5.5 KiB
Plaintext
142 lines
5.5 KiB
Plaintext
Battery state: where the systems publish it. Collected 2026-11-11 for McdeSys
|
|
mcde_sys_battery (ext/src/mcde/lib/McdeSys/{netbsd,linux}.c).
|
|
|
|
== Linux: refs/linux/7.0.0/Documentation/ABI/testing/sysfs-class-power
|
|
-- lines 30-50 (type)
|
|
What: /sys/class/power_supply/<supply_name>/type
|
|
Date: May 2010
|
|
Contact: linux-pm@vger.kernel.org
|
|
Description:
|
|
Describes the main type of the supply.
|
|
|
|
Access: Read
|
|
Valid values: "Battery", "UPS", "Mains", "USB", "Wireless"
|
|
|
|
**Battery and USB properties**
|
|
|
|
What: /sys/class/power_supply/<supply_name>/current_avg
|
|
Date: May 2007
|
|
Contact: linux-pm@vger.kernel.org
|
|
Description:
|
|
Battery:
|
|
|
|
Reports an average IBAT current reading for the battery, over
|
|
a fixed period. Normally devices will provide a fixed interval
|
|
in which they average readings to smooth out the reported
|
|
value.
|
|
-- lines 263-280 (capacity)
|
|
What: /sys/class/power_supply/<supply_name>/capacity
|
|
Date: May 2007
|
|
Contact: linux-pm@vger.kernel.org
|
|
Description:
|
|
Fine grain representation of battery capacity.
|
|
|
|
Access: Read
|
|
|
|
Valid values: 0 - 100 (percent)
|
|
|
|
What: /sys/class/power_supply/<supply_name>/capacity_alert_max
|
|
Date: July 2012
|
|
Contact: linux-pm@vger.kernel.org
|
|
Description:
|
|
Maximum battery capacity trip-wire value where the supply will
|
|
notify user-space of the event. This is normally used for the
|
|
battery discharging scenario where user-space needs to know the
|
|
battery has dropped to an upper level so it can take
|
|
-- lines 488-505 (status)
|
|
What: /sys/class/power_supply/<supply_name>/status
|
|
Date: May 2007
|
|
Contact: linux-pm@vger.kernel.org
|
|
Description:
|
|
Represents the charging status of the battery. Normally this
|
|
is read-only reporting although for some supplies this can be
|
|
used to enable/disable charging to the battery.
|
|
|
|
Access: Read, Write
|
|
|
|
Valid values:
|
|
"Unknown", "Charging", "Discharging",
|
|
"Not charging", "Full"
|
|
|
|
What: /sys/class/power_supply/<supply_name>/charge_behaviour
|
|
Date: November 2021
|
|
Contact: linux-pm@vger.kernel.org
|
|
Description:
|
|
|
|
== Linux: refs/linux/7.0.0/Documentation/power/power_supply_class.rst (ENERGY_*, CHARGE_*, POWER_NOW, units)
|
|
51: All voltages, currents, charges, energies, time and temperatures in µV,
|
|
52: µA, µAh, µWh, seconds and tenths of degree Celsius unless otherwise
|
|
63:| **Because both "charge" (µAh) and "energy" (µWh) represents "capacity" |
|
|
67:| attributes represents capacity in µAh only. |
|
|
68:| - `ENERGY_*` |
|
|
69:| attributes represents capacity in µWh only. |
|
|
127:ENERGY_FULL_DESIGN, ENERGY_EMPTY_DESIGN
|
|
130:CHARGE_FULL, CHARGE_EMPTY
|
|
136:ENERGY_FULL, ENERGY_EMPTY
|
|
140: the current charge counter (in µAh). This could easily
|
|
|
|
== NetBSD: src/sys/dev/acpi/acpi_bat.c:710-725 (sensor names and flags)
|
|
INITDATA(ACPIBAT_PRESENT, ENVSYS_INDICATOR, "present");
|
|
INITDATA(ACPIBAT_DCAPACITY, ENVSYS_SWATTHOUR, "design cap");
|
|
INITDATA(ACPIBAT_LFCCAPACITY, ENVSYS_SWATTHOUR, "last full cap");
|
|
INITDATA(ACPIBAT_DVOLTAGE, ENVSYS_SVOLTS_DC, "design voltage");
|
|
INITDATA(ACPIBAT_VOLTAGE, ENVSYS_SVOLTS_DC, "voltage");
|
|
INITDATA(ACPIBAT_CHARGERATE, ENVSYS_SWATTS, "charge rate");
|
|
INITDATA(ACPIBAT_DISCHARGERATE, ENVSYS_SWATTS, "discharge rate");
|
|
INITDATA(ACPIBAT_CAPACITY, ENVSYS_SWATTHOUR, "charge");
|
|
INITDATA(ACPIBAT_CHARGING, ENVSYS_BATTERY_CHARGE, "charging");
|
|
INITDATA(ACPIBAT_CHARGE_STATE, ENVSYS_BATTERY_CAPACITY, "charge state");
|
|
|
|
#undef INITDATA
|
|
|
|
sc->sc_sensor[ACPIBAT_CHARGE_STATE].value_cur =
|
|
ENVSYS_BATTERY_CAPACITY_NORMAL;
|
|
|
|
-- acpi_bat.c:545-566 (rates in uW, charge in uWh, charging 0/1)
|
|
state = elm[ACPIBAT_BST_STATE].Integer.Value;
|
|
if ((state & ACPIBAT_ST_CHARGING) != 0) {
|
|
/* XXX rate can be invalid */
|
|
rate = elm[ACPIBAT_BST_RATE].Integer.Value;
|
|
sc->sc_sensor[ACPIBAT_CHARGERATE].state = ENVSYS_SVALID;
|
|
sc->sc_sensor[ACPIBAT_CHARGERATE].value_cur = rate * 1000;
|
|
sc->sc_sensor[ACPIBAT_DISCHARGERATE].state = ENVSYS_SINVALID;
|
|
sc->sc_sensor[ACPIBAT_CHARGING].state = ENVSYS_SVALID;
|
|
sc->sc_sensor[ACPIBAT_CHARGING].value_cur = 1;
|
|
} else if ((state & ACPIBAT_ST_DISCHARGING) != 0) {
|
|
rate = elm[ACPIBAT_BST_RATE].Integer.Value;
|
|
sc->sc_sensor[ACPIBAT_DISCHARGERATE].state = ENVSYS_SVALID;
|
|
sc->sc_sensor[ACPIBAT_DISCHARGERATE].value_cur = rate * 1000;
|
|
sc->sc_sensor[ACPIBAT_CHARGERATE].state = ENVSYS_SINVALID;
|
|
sc->sc_sensor[ACPIBAT_CHARGING].state = ENVSYS_SVALID;
|
|
sc->sc_sensor[ACPIBAT_CHARGING].value_cur = 0;
|
|
} else {
|
|
sc->sc_sensor[ACPIBAT_CHARGING].state = ENVSYS_SVALID;
|
|
sc->sc_sensor[ACPIBAT_CHARGING].value_cur = 0;
|
|
sc->sc_sensor[ACPIBAT_CHARGERATE].state = ENVSYS_SINVALID;
|
|
sc->sc_sensor[ACPIBAT_DISCHARGERATE].state = ENVSYS_SINVALID;
|
|
}
|
|
|
|
/* Remaining capacity. */
|
|
val = elm[ACPIBAT_BST_CAPACITY].Integer.Value;
|
|
sc->sc_sensor[ACPIBAT_CAPACITY].value_cur = val * 1000;
|
|
sc->sc_sensor[ACPIBAT_CAPACITY].state = ACPIBAT_VAL_ISVALID(val);
|
|
|
|
== NetBSD: src/sys/dev/acpi/acpi_acad.c:262
|
|
(void)strlcpy(sc->sc_sensor.desc, "connected", ENVSYS_DESCLEN);
|
|
|
|
== NetBSD: how envstat(8) reads them, src/usr.sbin/envstat/envstat.c:527, 660-730
|
|
rval = prop_dictionary_recv_ioctl(fd, ENVSYS_GETDICTIONARY, &dict);
|
|
|
|
/* get current value */
|
|
obj1 = prop_dictionary_get(obj, "cur-value");
|
|
if (obj1)
|
|
sensor->cur_value = prop_number_signed_value(obj1);
|
|
|
|
/* get max value */
|
|
obj1 = prop_dictionary_get(obj, "max-value");
|
|
if (obj1)
|
|
sensor->max_value = prop_number_signed_value(obj1);
|
|
-- state strings, src/sys/dev/sysmon/sysmon_envsys_tables.c:64-65
|
|
{ ENVSYS_SVALID, -1, "valid" },
|
|
{ ENVSYS_SINVALID, -1, "invalid" },
|